Resources

Account Log On

Login

Register. It's free, quick and easy.
Sign up.


Get FREE Stuff & Specials. Sign up for our email newsletter

2010 Catalogue

Store Currency: 

Australian Tax Mode:
Prices in Australian dollars.

Easy Ways of Buy


Search | Advanced Search

Find us on Facebook
Follow us on Twitter





Click here to view larger image


Click here to view larger image


E-mail this product to a friend Email this product to a friend

Kestrel 4250 Racing Weather Meter

Stock #:KES-084250-AUS

Price: $499.00
Web Price: $499.00 inc GST


Qty:   

Previous  Up  Next" 

Kestrel and Performance Racing

4250 Racing Weather Tracker Virtual Tour

The First Step to Optimizing PerformanceKnowing the current environmental conditions can often be the difference between finishing in the money and just finishing.

Even slight changes in air density, water grains, and density altitude can dramatically affect a machine’s performance. With the added ability to easily measure and track these and other critical factors, such as absolute pressure, temperature, humidity, wind speed and barometric pressure, the Kestrel 4250 Racing Weather Tracker arms racers with the accurate weather data needed to make those last minute jetting or tuning decisions.

Real-Time Data

Conditions on the track can often vary greatly from those in the pits. The rugged, portable and easy to use Kestrel 4250 Racing Weather Tracker quickly provides racers and pit crews with the most accurate and up-to-date data available where you need it most — at the track. It allows tuners to determine what last minute changes need to be made based on the current local conditions, even immediately before the first lap around the track or pass down the drag strip — giving you that competitive edge at a fraction of the cost of other systems on the market.

Kestrel PC InterfaceData Logging

The Kestrel 4250 Racing Weather Tracker also features an automatic and manual data storage function, allowing you to easily keep logs of race day conditions from track to track, year to year. The Kestrel PC Interface and Communicator Software allows data to be easily transferred directly to a PC or laptop making long-term storage, in-depth analysis, and detailed charting of stored data a breeze.

Kestrel 4250 Measures  

density altitude
Density altitude

water grains / moisture content
Water grains / moisture content

air density
Air density

station pressure
Station pressure

relative air density
Relative air density

humidity
Humidity

wind speed
Wind speed

temperature
Temperature in °F or °C

Kestrel 4250 Features

  • Waterproof and floats
  • Backlight for low light conditions
  • Data logger (automatic and manual)
  • Customizable data storage – 3200 data points
  • Multi-Function 3-line display
  • Convenient averaging mode
  • Data charting
  • Humidity sensor can be recalibrated in the field with our Relative Humidity Calibration Kit.
  • User-replaceable impeller
  • Flip-top impeller cover
  • Upload to a computer (with optional interface)
  • Five languages (English, French, Spanish, German, and Italian)
  • US Patent Nos. 5,783,753 and 5,939,645 and 6,257,074
  • 5-year warranty
  • Assembled in the USA

Kestrel 4250 Includes

  • Soft carry pouch
  • Neck lanyard
  • Batteries – 2 AAA
  • Kestrel Certificate of Conformity


Specifications

Measurement
Response Time
Units Operational Range Resolution Accuracy (+/-) Specification Range
Wind Speed
1 second
m/s 0.4 to 60.0 m/s 0.1 Larger of 3% of reading or least significant digit 0.4 to 40.0 m/s
ft/min 59 to 11,948 ft/min 1 59 to 7877 ft/min
km/h 1.0 to 218.0 km/h 0.1 1.0 to 144.0 km/h
mph 0.8 to 135.0 mph 1 0.8 to 89.0 mph
knots 0.6 to 118.3 kt 0.1 0.6 to 78.0 kt
Beaufort 0 to 12 B 0.1 0 to 12 B
1 inch diameter impeller with precision axle and sapphire bearings. Off-axis accuracy -1% @ 5º off-axis; -2% @ 10º; -3% @ 15º. Calibration drift < 1% after 100 hours use at 16 MPH / 7 m/s. Sustained operation above 60 MPH / 27 m/s will wear impeller ra
Temperature
1 second
°F -49.0 to 257.0 °F 0.1 1.8 °F -20.0 to 158.0 °F
°C -45.0 to 125.0 °C 0.1 1.0 °C -29.0 to 70.0 °C
Measures air, water and snow temperature. Thermally isolated, hermetically sealed, precision thermistor mounted externally (US Patent 5,939,645). Calibration drift negligible.
Relative Humidity
1 minute
%RH 0.0 to 100.0 % 0.1 3.0 %RH 5.0 to 95.0 % non-condensing
Polymer capacitive humidity sensor mounted in thin-walled chamber external to case for rapid, accurate response (US Patent 6,257,074). (To achieve stated relative humidity accuracy, unit must be permitted to equilibrate to external temperature when expos
Pressure
1 second
inHg 0.3 to 32.5 inHg 0.01 0.05 inHg At 77.0 °F, 22.1 to 32.5 inHg
hPa / mb 10.0 to 1100.0 hPa / mb 0.1 1.5 hPa / mb At 25.0 °C, 750 to 1100hPa / mb
PSI 0.15 to 16.0 PSI 0.01 0.02 PSI At 77.0 °F, 10.9 to 16.0 PSI
Monolithic silicon piezoresistive pressure sensor with second-order temperature correction. Maximum error over temperature range 32 to158 °F (0 to70°C) , +/- 0.06 inHg / +/-2.0 hPa. Calibration drift typically -0.03 inHg / -1.0 hPa per year. Pressure sen
Altitude
1 second
ft -6000 to 30000 ft 1 50 ft At 77.0 °F, <19,700 ft. Max error +/- 98 ft
m -2000 to 9000 m 1 15 m At 25.0 °C, <6,000 m. Max error +/- 30 m
Temperature compensated pressure (barometric) altimeter.
Wind Chill
1 second
°F 0.7 to 135.0 MPH, -49.0 to 257.0 °F 0.1 1.8 °F 1.8 to 89.0 mph, -50.0 to 50.0 °F
°C 0.4 to 60.0 m/s, -45.0 to 125.0 °C 0.1 1.0 °C 0.4 to 40 m/s, -45.6 to 10.0 °C
Calculated from the primary measurements of wind speed and temperature. Utilizes the NWS Wind Chill Temperature (WCT) Index, revised 2001, with wind speed adjusted by a factor of 1.5 to yield equivalent results to wind speed measured at 10 m above ground
Heat Index
1 minute
°F 0.0 to 100.0 %RH, -49.0 to 257.0 °F 0.1 3.6 °F 70.0 to 130.0 °F, 0 to 100% RH
°C 0.0 to 100.0 %RH, -45.0 to 125.0 °C 0.1 2.0 °C 21.1 to 54.4 °C, 0 to 100 %RH
Calculated from the primary measurements of temperature and relative humidity. Utilizes the NWS Heat Index (HI) tables. (Specification temperature limits established by HI tables.)
Dewpoint
1 minute
°F 0.0 to 100.0 %RH, -49.0 to 257.0 °F 0.1 3.6 °F -20.0 to 158.0 °F, 20.0 to 95.0% RH
°C 0.0 to 100.0 %RH, -45.0 to 125.0 °C 0.1 2.0 °C -29.0 to 70.0 °C, 20.0 to 95.0 %RH
Calculated from the primary measurements of temperature and relative humidity. Temperature to which the air would need to be cooled at a constant pressure to become saturated.
Wet Bulb Temperature
1 minute
°F -49.0 to 257.0 °F, 0.0 to 100.0 %RH, 8.86 to 32.48 inHg 0.1 3.6 °F 32.0 to 100.0 °F, 5.0 to 95.0% RH, 8.86 to 32.48 inHg, <19700 ft
°C -45.0 to 125.0 °C, 0.0 to 100.0 %RH, 300.0 to 1100.0 hPa 0.1 2.0 °C 0.0 to 37.8 °C, 5.0 to 95.0 %RH, -2000.0 to 9000.0 hPa, <6000 m
Calculated from the primary measurements of temperature, relative humidity and pressure. Temperature indicated by a wet bulb psychrometer.
Density Altitude
1 second
ft -49.0 to 257.0 °F, 0.0 to 100.0 % RH, 8.86 to 32.48 inHg 1 246 32.0 to 100.0 °F, 5.0 to 95.0 %RH, 8.86 to 32.48 inHg, <19700 ft
m -45.0 to 125.0 °C, 0.0 to 100.0 %RH, 300.0 to 1100.0 hPa 1 75 0.0 - 37.8 °C, 5.0 to 95.0 %RH, -2000 to 9000 hPa, <6000 m
Calculated from the primary measurements of temperature, relative humidity and pressure. Air density converted to equivalent sea level elevation at the International Standard Atmosphere.
Air Density
1 minute
lb/ft3 -49.0 to 257.0 °F, 0.0 to 100.0 % RH, 8.86 to 32.48 inHg 0.001 '+/-2% 32.0 to 158.0 °F, 5.0 to 95.0 % RH, 22.10 - 32.48 inHg
kg/m3 -45.0 to 125.0 °C, 0.0 to 100.0 %RH, 300.0 to 1100.0 hPa 0.001 '+/-2% 0.0 - 70.0 C, 5-95%, 750-1100hPA
Calculated from the primary measurements of temperature, relative humidity and pressure.
Relative Air Density
1 minute
% -49.0 to 257.0 °F, 0.0 to 100.0 % RH, 8.86 to 32.48 inHg 0.1 +/-2% 32.0 to 158.0 °F, 5.0 to 95.0 % RH,
22.10 - 32.48 inHg
Calculated from the primary measurements of temperature, relative humidity and pressure.
Moisture Content (Water Grains)
1 minute
gpp 0.000 to 5000.0 gpp 0.1 typical accuracy 10% -20 to 130°F, 5 to 95% RH, 8.86 to 32.48 inHg
g/kg 0.00 to 720.0 g/kg 0.01 typical accuracy 10% -29 to 54°C, 5 to 95% RH, 300.0 to 1100.0 hPa
Calculated from the primary measurements of temperature, relative humidity and pressure. The measure of Grains/lb of dry air, called the humidity ratio, is an indication of the mass of water vapor in air.
Max/Avg Wind Speed,
Crosswind, Headwind/Tailwind
One-button clear and restart of Max Wind Gust and Average Wind measurement.
Data Storage / Display Minimum, maximum, average and logged history stored and displayed for every measured value. 3200-point data logger with graphical display. Auto data storage; interval settable from 2 seconds to 12 hours. Manual data capture.
Data Upload Requires optional PC interface (NK PN-0830) and provided software. RS-232 connection with USB adapter available.
Display Multifunction, multi-digit programmable dot-matrix display.
Display Update 1 second.
Display Backlight Choice of aviation green or visible red electroluminescent backlight. Automatic or manual activation.
Clock / Calendar Real-time hours:minutes:seconds clock, calendar, automatic leap-year adjustment.
Operational Temperature Range
(LCD and Batteries)
The operational temperature range of the liquid crystal display and batteries is 14° F to 131° F / -10 °C to 55 °C. Beyond the limits of the operational temperature range, the unit must be maintained within range and exposed for minimum time necessary to
Storage Temperature -22 °F to 140 °F / -30 °C to 60 °C.
Auto Shutdown User-selectable: 15 or 60 minutes with no key presses or disabled.
Languages English, French, German, Italian, Spanish.
Certifications CE certified. Individually tested to NIST-traceable standards (written certificate of tests available at additional charge).
Batteries AAA Alkaline, two, included. Average life, 400 hours of use, +/-depending on backlight use.
Environmental Waterproof (IP67 standard). Drop-tested (MIL.STD.810F; unit only. Substantial impact may damage replaceable impeller.).
Dimensions Unit 5.0 x 1.8 x 1.1 in / 12.7 x 4.5 x 2.8 cm.
Weight Unit 3.6 oz / 102 g.
Kestrel Meters are designed and manufactured at NK’s facility in Boothwyn, Pennsylvania, and are individually calibrated at the time of manufacture. Every Kestrel Meter comes with a Certificate of Conformity to document the unit’s accuracy—all Kestrel measurements are traceable to the National Institute of Standards and Technology, ensuring the highest level of reliability. Additional NIST Calibration and Certification services are available.


370 x 860 mm, White UV Stabilised Unlaminated, Polywoven Bag / Sack
ProEarth Sand Bag 370 x 860 mm, White UV Stabilised Unlaminated, Polywoven Bag / Sack