Kestrel 4000 Pocket Weather Meter in Orange

Stock #:KES-0840ORG-AUS

Price: $579.00
Web Price: $579.00 inc GST


Qty:   

Previous  Up  Next" 

Kestrel 4000 Pocket Weather Tracker

In 2000, we introduced the Kestrel 4000 Pocket Weather Tracker, and today it is still the most comprehensive pocket weather meter on the market. For just under 4 ounces, you get every environmental reading with the press of a single button. The 4000 is unparalleled in its ease of use and totally customizable navigation and data display. In addition to measuring the current conditions, it tracks and stores up to 2000 sets of data, and data can be uploaded to a PC with the optional Kestrel Interface.

Durable? You bet. The 4000 has been subjected to impact, water submersion and extreme temperature tests, and keeps on working. Kestrel 4000’s have been put to the test in some of the harshest conditions on the planet. U.S. Special Forces, combat weather teams, wildland firefighters, smoke jumpers, Mt. Everest expeditions and IRL pit crews are just a few who rely on a Kestrel 4000 to provide them with the crucial environmental data they need. Watch the Weather Channel during a hurricane, and you’re sure to spot a Kestrel 4000 being wielded by an intrepid on-screen meteorologist.

Due to popular demand in a range of applications, the Kestrel 4000 is available in Gray, Olive Drab, and Safety Orange.

Available in the NV Configuration

Military personnel and pilots flying in darkness are often concerned with preserving their night vision. Due to overwhelming demand from our military customers, the Kestrel NV line was added in 2005.

The Kestrel 4000NV is available with an Olive Drab case or a Desert Tan case. The unit has a night-vision preserving backlight which helps users to sustain natural night vision. The NV's backlight incorporates an optical filter to reduce overall brightness and minimize blue and green spectrum light to preserve night vision. Additionally, NV backlights are also much dimmer than a standard backlight, making it more difficult to detect with the naked eye in night operations. This backlight appears soft greyish pink, not red, and is still in the visible spectrum, so is not compatible with night-vision equipment.

It takes 30 to 45 minutes for the average eye to adapt to darkness and maximize night vision. Even a short burst of white, yellow, green or blue light “bleaches out” the rod cell photoreceptors in the eye and causes night blindness until the entire adaptation process can take place again. Light in the red spectrum does not cause this “bleaching out”, preventing night blindness and night vision fatigue.

Kestrel 4000 Virtual Tour Kestrel Family Virtual Tour

Kestrel 4000 Measures

  • Barometric pressure
  • Pressure trend
  • Altitude
  • Relative humidity
  • Heat stress index
  • Dewpoint
  • Wet bulb temperature
  • Density altitude
  • Wind chill
  • Air, water, and snow temperature
  • Current wind speed
  • Average wind speed
  • Maximum wind gust

Kestrel 4000 Features

  • Waterproof and floats
  • Easy to read, backlit display
  • Time and date
  • Exterior temperature, humidity, and pressure sensors for fast and accurate readings
  • Humidity sensor can be recalibrated in the field with our Relative Humidity Calibration Kit.
  • Minimum, maximum, and average values
  • Automatically store measurements, even when the unit is turned off
  • Manually store measurements with the press of a button
  • Customizable data storage - 4000 data points
  • Graph and recall trends
  • Customize screens to display user-selected measurements
  • Data charting
  • Data upload (with optional interface)
  • Five languages (English, French, Spanish, German, and Italian)
  • User-replaceable impeller
  • Flip-top impeller cover allows use of other functions while protecting the impeller
  • US Patent Nos. 5,783,753 and 5,939,645 and 6,257,074
  • All instruments and accessories are completely assembled in the USA
  • 5-year warranty

Kestrel 4000 Includes

  • Soft carry pouch
  • Neck lanyard
  • Batteries - 2 AAA
  • Kestrel Certificate of Conformity

Specifcations

Measurement
Response Time
Units Operational Range Resolution Accuracy (+/-) Specification Range
Wind Speed
1 second  
m/s 0.4 to 60.0 m/s 0.1 Larger of 3% of reading or least significant digit 0.4 to 40.0 m/s
ft/min 59 to 11,948 ft/min 1 59 to 7877 ft/min
km/h 1.0 to 218.0 km/h 0.1 1.0 to 144.0 km/h
mph 0.8 to 135.0 mph 1 0.8 to 89.0 mph
knots 0.6 to 118.3 kt 0.1 0.6 to 78.0 kt
Beaufort 0 to 12 B 0.1 0 to 12 B
1 inch diameter impeller with precision axle and sapphire bearings.  Off-axis accuracy -1% @ 5º off-axis; -2% @ 10º; -3% @ 15º.  Calibration drift < 1% after 100 hours use at 16 MPH / 7 m/s.  Sustained operation above 60 MPH / 27 m/s will wear impeller rapidly and may cause destruction of impeller.  Replacement impeller (NK PN-0801) may be field-installed without tools (US Patent 5,783,753).
Temperature  
1 second
°F -49.0 to 257.0 °F 0.1 1.8 °F -20.0 to 158.0 °F
°C -45.0 to 125.0 °C 0.1 1.0 °C -29.0 to 70.0 °C
Measures air, water and snow temperature.  Thermally isolated, hermetically sealed, precision thermistor mounted externally (US Patent 5,939,645).  Calibration drift negligible.
Relative Humidity
1 minute 
%RH 0.0 to 100.0 % 0.1 3.0 %RH  5.0 to 95.0 % non-condensing
Polymer capacitive humidity sensor mounted in thin-walled chamber external to case for rapid, accurate response (US Patent 6,257,074).  (To achieve stated relative humidity accuracy, unit must be permitted to equilibrate to external temperature when exposed to large, rapid temperature changes and must be kept out of direct sunlight.)  Calibration drift +/- 2% over 24 months. Relative humidity may be recalibrated at factory or in field using Kestrel Humidity Calibration Kit (NK PN-0802).
Pressure  
1 second  
(mb & PSI 4000 model only)
inHg 0.3 to 32.5 inHg 0.01 0.05 inHg At 77.0 °F, 22.1 to 32.5 inHg
hPa / mb 10.0 to 1100.0 hPa / mb 0.1 1.5 hPa / mb At 25.0 °C, 750 to 1100 hPa / mb
PSI 0.15 to 16.0 PSI 0.01 0.02 PSI At 77.0 °F, 10.9 to 16.0 PSI
Monolithic silicon piezoresistive pressure sensor with second-order temperature correction. Maximum error over temperature range 32 to 158 °F (0 to 70°C) , +/- 0.06 inHg / +/-2.0 hPa. Calibration drift typically -0.03 inHg / -1.0 hPa per year. Pressure sensor may be recalibrated at factory or in field.
Altitude  
1 second  
ft -6000 to 30000 ft 1 50 ft At 77.0 °F, <19,700 ft. Max error +/- 98 ft
m -2000 to 9000 m 1 15 m At 25.0 °C, <6,000 m.  Max error +/- 30 m
Temperature compensated pressure (barometric) altimeter. 
Wind Chill  
1 second  
°F 0.7 to 135.0 MPH, -49.0 to 257.0 °F 0.1 1.8 °F 1.8 to 89.0 mph, -50.0 to 50.0 °F
°C 0.4 to 60.0 m/s, -45.0 to 125.0 °C 0.1 1.0 °C 0.4 to 40 m/s, -45.6 to 10.0 °C
Calculated from the primary measurements of wind speed and temperature.  Utilizes the NWS Wind Chill Temperature (WCT) Index, revised 2001, with wind speed adjusted by a factor of 1.5 to yield equivalent results to wind speed measured at 10 m above ground.  (Specification temperature limits established by WCT Tables.)
Heat Index  
1 minute  
°F 0.0 to 100.0 %RH, -49.0 to 257.0 °F 0.1 3.6 °F 70.0 to 130.0 °F, 0 to 100% RH
°C 0.0 to 100.0 %RH, -45.0 to 125.0 °C 0.1 2.0 °C 21.1 to 54.4 °C, 0 to 100 %RH
Calculated from the primary measurements of temperature and relative humidity.  Utilizes the NWS Heat Index (HI) tables.  (Specification temperature limits established by HI tables.) 
Dewpoint  
1 minute  
°F 0.0 to 100.0 %RH, -49.0 to 257.0 °F 0.1 3.6 °F -20.0 to 158.0 °F, 20.0 to 95.0% RH
°C 0.0 to 100.0 %RH, -45.0 to 125.0 °C 0.1 2.0 °C -29.0 to 70.0 °C, 20.0 to 95.0 %RH
Calculated from the primary measurements of temperature and relative humidity. Temperature to which the air would need to be cooled at a constant pressure to become saturated.
Wet Bulb Temperature 1 minute   °F -49.0 to 257.0 °F, 0.0 to 100.0 %RH, 8.86 to 32.48 inHg 0.1 3.6 °F 32.0 to 100.0 °F, 5.0 to 95.0% RH, 8.86 to 32.48 inHg, <19700 ft
°C -45.0 to 125.0 °C, 0.0 to 100.0 %RH, 300.0 to 1100.0 hPa 0.1 2.0 °C 0.0 to 37.8 °C, 5.0 to 95.0 %RH, -2000.0 to 9000.0 hPa, <6000 m
Calculated from the primary measurements of temperature, relative humidity and pressure. Temperature indicated by a wet bulb psychrometer.
Density Altitude 
1 second  
ft -49.0 to 257.0 °F, 0.0 to 100.0 % RH, 8.86 to 32.48 inHg 1 246 32.0 to 100.0 °F, 5.0 to 95.0 %RH, 8.86 to 32.48 inHg, <19700 ft
m -45.0 to 125.0 °C, 0.0 to 100.0 %RH, 300.0 to 1100.0 hPa 1 75 0.0 - 37.8 °C, 5.0 to 95.0 %RH, -2000 to 9000 hPa, <6000 m
Calculated from the primary measurements of temperature, relative humidity and pressure.  Air density converted to equivalent sea level elevation at the International Standard Atmosphere.
Max/Avg Wind Speed (Air Velocity),
Crosswind, Headwind/Tailwind
One-button clear and restart of Max Wind Gust and Average Wind measurement.
Data Storage / Display Minimum, maximum, average and logged history stored and displayed for every measured value. 4000-point data logger with graphical display. Auto data storage; interval settable from 2 seconds to 12 hours. Manual data capture.  
Data Upload Requires optional PC interface (NK PN-0830) and provided software. RS-232 connection with USB adapter available.
Display Multifunction, multi-digit programmable dot-matrix display.
Display Update 1 second.
Display Backlight Choice of aviation green or visible red electroluminescent backlight. Automatic or manual activation.
Clock / Calendar Real-time hours:minutes:seconds clock, calendar, automatic leap-year adjustment.
Operational Temperature Range
(LCD and Batteries)
The operational temperature range of the liquid crystal display and batteries is 14° F to 131° F / -10 °C to 55 °C. Beyond the limits of the operational temperature range, the unit must be maintained within range and exposed for minimum time necessary to take reading.
Storage Temperature -22 °F to 140 °F / -30 °C to 60 °C.
Auto Shutdown User-selectable:  15 or 60 minutes with no key presses or disabled.
Languages English, French, German, Italian, Spanish.
Certifications CE certified. Individually tested to NIST-traceable standards (written certificate of tests available at additional charge).  
Batteries AAA Alkaline, two, included. Average life, 400 hours of use, +/-depending on backlight use.
Environmental Waterproof (IP67 standard). Drop-tested (MIL.STD.810F; unit only. Substantial impact may damage replaceable impeller.).
Dimensions Unit 5.0 x 1.8 x 1.1 in / 12.7 x 4.5 x 2.8 cm.
Weight Unit 3.6 oz / 102 g.
Kestrel Meters are designed and manufactured at NK’s facility in Boothwyn, Pennsylvania, and are individually calibrated at the time of manufacture. Every Kestrel Meter comes with a Certificate of Conformity to document the unit’s accuracy—all Kestrel measurements are traceable to the National Institute of Standards and Technology, ensuring the highest level of reliability. Additional NIST Calibration and Certification services are available.


370 x 860 mm, White UV Stabilised Unlaminated, Polywoven Bag / Sack
ProEarth Sand Bag 370 x 860 mm, White UV Stabilised Unlaminated, Polywoven Bag / Sack
Davis Vantage Vue
Davis Vantage Vue
SPOT 2, Satellite GPS Messenger
SPOT 2, Satellite GPS Messenger

GME MT410GAUS 406 MHz PLB, Personal Locator Beacon with GPS, Manual Activation

Kestrel 3000 Pocket Weather Meter
ProEarth High Visibility Field Vest
ProEarth High Visibility Field Vest